China Inoculating Loop & Needle Sterilizer (φ35mm) | KETHINK

Bunsen burner, alcohol lamp is a kind of disinfection tool that is commonly used in the laboratory. Because it is heated and disinfected by an open flame, it brings some insecurity to the operation of the laboratory.

Based on the electronic infrared principle, KETHINK inoculating loop sterilizer is an electric loop sterilized tool that perfectly replaces alcohol lamp in the lab.The temperature in the heating zone is as high as 825℃, and the sterilization only takes 5 to 7 seconds.

Model NO: KT-IS800B

MOQ: 1 set

Warranty: 2 years for free,technical support for life

Delivery: within 5-7 working days

CONTACT NOW

KT-IS800B Electric Inoculating Loop Sterilizer Product Specification

  • General Introduction

KT-IS800B inoculating loop sterilizer is used in degassing for inoculating loops and needles, instead of alcohol lamps.

Due to its convenience, sterilizer is wildly used in the environment of biosafety cabinets, clean benches.

They are also used besides exhaust fans or on mobile vans.

  • Applications

Widely used in biosafety cabinets, clean bench, near exhaust fan, mobile vehicles, even outdoor and other severe environment can be easily used.

  • Safety, convenient. Totally take the place of alcohol lamps.
  • Only 5 seconds to 7 seconds are needed, because of its highest temperature of 825℃.
  • Smart, light, easy to handle.
  • Used in anaerobic chamber is allowed.
  • Podzolic organics prevent pollutions effectively.
  • Smart technique makes it possible to use for a long time and much safe.
Parameter KT-IS800B
Max. temp. in central zone825℃±25℃
Max. outer diameter of sterilization goodsφ35mm
Length of heating zone100mm
Heating time15min
Ambient temperature5℃~40℃
Fuse250V 3A  φ5×20
VoltageAC220V or AC110V, 50-60Hz
Power250W
Dimension(mm)130*120*200
Weight(kg)1.3
  • Operation manual *1pcs
  • Fuse (250V 3A) *3pcs
  • Certification *1pcs
  • FAQ

1) Put the sterilizer on work station, make sure no inflammable and explosive dangerous goods around it.
2) Plug the electrical cord into the appropriate outlet. The unit must be properly grounded.
3) The red indicator light will light up when the switch is on the “High” position, the sterilizer will reach the optimum sterilizing temperature(820℃) in 15 minutes. The green indicator light will light up when the switch is on the “Low” position, the temperature of heater will fall which is about 400℃.
Note: The Bacti-Cinerator Sterilizer with a sound of “di” each 60 minutes when it uses for 3 hours, The sterilizer will stop heating automatic when it uses continuously for 3.5 hours. If you want to continue to use it, please put the switch on “OFF” position, then put the switch on “High” or “Low” position.
4) Gently insert the loop or needle, attached to an insulated loop holder, into the heater element. Avoid scraping the sides of the element to ensure the longevity of your loop and heater element. The loop should remain within the heater element a minimum of five seconds.

Use infrared heat to incinerate organic material deep within the ceramic funnel tube with a temperature of up to 900 degrees . Sterilization takes only 5 to 7 seconds.

Note:Only insulated loop holders should be used when inserting inoculating loops or needles into the heater element.